Telephone
1-607-698-4430
|
|
Fax
1-607-698-4434
|
|
Email
|
|
Live Help
|
|
Investigating loading effects in SJ MEPLA Application of any loads
- Face loads.
- Dead weight (by specifying the direction of the gravitational force)
- Concentrated loads with defined area distribution (man's weight).
- Line loads running in any direction.
- Climatic loads for insulation glass units (pressure and temperature differences, height differences).
Calculation of insulating glass
- Taking into account the gas pressure laws in the cavity.
- Any load conditions (pressure differences, thermal expansion of the gas, external loads, pendulum impact, ...).
- Up to 4-fold insulated glass units.
- Non-linear consideration of the spacer possible.
For most types of support, calculation with contact is possible (glass fixings, linear supports with raised corners, ...)!
Dynamic simulation of the pendulum impact test according to DIN EN 12600
- For any system with glass unit structure.
- The drop height of the pendulum and the impact point can be freely selected.
Other properties
- Pressure shock stresses (wind gusts, stresses due to explosions, ...).
- Computation log with all basic data, specifications and results.
-
Graphical representation of the variation of force, deformation and stress
variation over the duration of the impact for any predefined points.
|
|
|